CS-H1108PLS — PoE Switch

The CS-H1108PLS is a poe switch for professional camera-network planning. Its listed port arrangement is 8x10/100Mbps PoE + 2x10/100Mbps uplink. The supported PoE standard is IEEE802.3af/at.

Use this model when the project needs a group of powered Ethernet connections. Check port speed, connector type and the power needed by each device. The catalog lists a total PoE budget of 100W. Where more than one budget is listed, confirm the ordered variant.

Plan cable routes, uplink capacity and installation space before final selection. Maximum power per port and the total system power budget are different limits; check both where applicable. Confirm equipment requirements, including startup and auxiliary loads, before connecting devices.

Key specifications

  • Ports: 8x10/100Mbps PoE + 2x10/100Mbps uplink

  • PoE standard: IEEE802.3af/at

  • Maximum PoE per port: 30W

  • Total PoE budget: 100W

  • Installation: Desktop or wall mount

  • Dimensions: 195x130x40mm

  • Protection: IP30

Power and data planning

Power and network capacity should be checked together. Identify the source at one end and the device at the other, then write down the required voltage or PoE standard, the peak wattage and the expected link speed. For equipment placed between a switch and a camera, draw the data path as well as the power path. This makes it easier to spot an incompatible port or connector before work starts on site.

Before specifying CS-H1108PLS, write down what will count as a successful installation. Ask which equipment it will work beside, what condition matters most and who will check it at handover. That keeps the documented specification tied to a decision: whether this exact configuration solves the stated task, whether another model should be compared or whether the site needs a short trial first.

What the specifications mean for the installer

Ports: 8x10/100Mbps PoE + 2x10/100Mbps uplink. Use the listed value as part of the complete power calculation. Check normal load and the conditions that create peak demand. Confirm connectors, cable, power source and approved load before commissioning. Document the final measurements so onsite staff can distinguish a hardware fault from a power shortfall during service.

Dimensions: 195x130x40mm. Compare the exact part number against the assembly drawing and the component to which it attaches. Check space for connectors, tools and service access. Measure the stack with a sample when available. A fit check at the bench saves time if an installer would otherwise first discover the mismatch at the work location.

Protection: IP30. Use the documented conditions to check the proposed location and the full assembly. Look at the cable entry, bracket and exposure as well as the device itself. Compare the exact revision with the project requirements, and log any separate approvals before the site relies on the installation.

How to verify the result

Test with the final cable route where you can. Cold startup, lamps, heaters and motor movement can change the demand of a connected camera. On a multiport device, add the expected loads together and check the total budget as well as the limit of each port. Save a port map and label both ends of the run so that a later fault can be isolated without disconnecting unrelated equipment.

Questions installers ask

Will it power every device on the project?

Power depends on the supported standards or electrical output, the endpoint requirement and the total available budget. For DC outputs, check voltage, polarity and connector type. For an Ethernet link, confirm speed and cable reach separately from whether the endpoint starts up.

Related products and resources

CS-POE33024PF — PoE Switch

CS-POE33108PF — PoE Switch

Browse all products

CS-H1108PLS poe switch product image
CS-H1108PLS poe switch product image