PRODUCT INFORMATION FOR SECURITY PROFESSIONALS
CS-I5LQ I-T-4mm — Thermal Bullet Camera
The CS-I5LQ I-T-4mm is a thermal bullet camera listed in the 2027 Q1 catalog. Optical image: 2880x1620@30fps. Thermal image: 256x192@25fps.
Consider this model where a project calls for thermal viewing. Compare the sensor resolution and lens with the target size and required coverage. A detection task is different from identification or temperature measurement; define the required result before choosing the configuration.
Check the mounting position, power, network and recording requirements for the exact model. Confirm any analytics or integration needed by the project with current documentation and test the result during commissioning.
Key specifications
Optical image: 2880x1620@30fps
Thermal image: 256x192@25fps
Thermal sensor: VOx uncooled focal-plane array
Visible lens: 4mm
Thermal lens: 3.2mm
Wide dynamic range: 120dB
Protection: IP67
Thermal and visible coverage
Start with what the operator must do with the image. Thermal viewing can help flag a heat contrast that needs attention, while a separate visible view may be needed to recognize context. Where the catalog lists both kinds of image, keep the sensor resolution, lens and intended job separate for each one. Size the coverage around the target size and location, then check the view in the same parts of the site where staff will use it.
Before specifying CS-I5LQ I-T-4mm, write down what will count as a successful installation. Ask which equipment it will work beside, what condition matters most and who will check it at handover. That keeps the documented specification tied to a decision: whether this exact configuration solves the stated task, whether another model should be compared or whether the site needs a short trial first.
What the specifications mean for the installer
Visible lens: 4mm. Confirm the needed view from the final mounting point. Get a clip with a test target at both the nearest and farthest positions that matter. If the project needs an overview and a tighter shot, compare the two views separately. Doing this before installation helps avoid a second visit to move a bracket or change the lens.
Wide dynamic range: 120dB. Treat the lighting figure as a design input and verify the condition at the site. Record near a bright door or after normal lights go out, depending on the task. Make sure reflections from nearby surfaces do not obscure the part of the scene the operator needs to review.
Protection: IP67. Use the documented conditions to check the proposed location and the full assembly. Look at the cable entry, bracket and exposure as well as the device itself. Compare the exact revision with the project requirements, and log any separate approvals before the site relies on the installation.
How to verify the result
Plan an acceptance test with targets at marked positions. Consider background temperature, weather, surface reflections and obstructions. Record what operators can tell from the thermal and visible views, and agree on what triggers follow-up. If temperature measurement or an alarm is required, confirm exactly which function the documented configuration supports and use the project procedure to test it.
Questions installers ask
Can the published detection distance be used as an identification distance?
Detection and identification are different tasks. Read the stated test conditions behind the distance figure and verify your intended task with the correct lens and target on site. Provide a visible camera or another confirmation step when the operator needs detail the thermal image cannot supply.
Related products and resources
CSP-I640R IT-13/19/25 — Thermal Bullet Camera