PRODUCT INFORMATION FOR SECURITY PROFESSIONALS
CSP-I640R IT-13/19/25 — Thermal Bullet Camera
The CSP-I640R IT-13/19/25 is a thermal bullet camera listed in the 2027 Q1 catalog. Thermal sensor: VOx uncooled FPA, 640x512. Thermal lens options: 9.1mm / 13mm / 19mm / 25mm, athermal fixed focus, F/1.0.
Consider this model where a project calls for thermal viewing. Compare the sensor resolution and lens with the target size and required coverage. A detection task is different from identification or temperature measurement; define the required result before choosing the configuration.
Check the mounting position, power, network and recording requirements for the exact model. Confirm any analytics or integration needed by the project with current documentation and test the result during commissioning.
Key specifications
Thermal sensor: VOx uncooled FPA, 640x512
Thermal lens options: 9.1mm / 13mm / 19mm / 25mm, athermal fixed focus, F/1.0
Storage: MicroSD up to 256GB
Protection: IP66
Thermal and visible coverage
Start with what the operator must do with the image. Thermal viewing can help flag a heat contrast that needs attention, while a separate visible view may be needed to recognize context. Where the catalog lists both kinds of image, keep the sensor resolution, lens and intended job separate for each one. Size the coverage around the target size and location, then check the view in the same parts of the site where staff will use it.
Before specifying CSP-I640R IT-13/19/25, write down what will count as a successful installation. Ask which equipment it will work beside, what condition matters most and who will check it at handover. That keeps the documented specification tied to a decision: whether this exact configuration solves the stated task, whether another model should be compared or whether the site needs a short trial first.
What the specifications mean for the installer
Thermal lens options: 9.1mm / 13mm / 19mm / 25mm, athermal fixed focus, F/1.0. Confirm the needed view from the final mounting point. Get a clip with a test target at both the nearest and farthest positions that matter. If the project needs an overview and a tighter shot, compare the two views separately. Doing this before installation helps avoid a second visit to move a bracket or change the lens.
Storage: MicroSD up to 256GB. Decide who needs to find and export a recording before specifying capacity. Include the planned recording schedule and retention target and confirm the actual supported storage media. A recorder or local storage figure by itself does not give the number of days of useful footage under a particular recording policy.
Protection: IP66. Use the documented conditions to check the proposed location and the full assembly. Look at the cable entry, bracket and exposure as well as the device itself. Compare the exact revision with the project requirements, and log any separate approvals before the site relies on the installation.
How to verify the result
Plan an acceptance test with targets at marked positions. Consider background temperature, weather, surface reflections and obstructions. Record what operators can tell from the thermal and visible views, and agree on what triggers follow-up. If temperature measurement or an alarm is required, confirm exactly which function the documented configuration supports and use the project procedure to test it.
Questions installers ask
Can the published detection distance be used as an identification distance?
Detection and identification are different tasks. Read the stated test conditions behind the distance figure and verify your intended task with the correct lens and target on site. Provide a visible camera or another confirmation step when the operator needs detail the thermal image cannot supply.
Related products and resources
CS-I5LQ I-T-4mm — Thermal Bullet Camera

